ååã®èšäºã
EthernetïŒFC ãã®ç¶ãã§ãNetApp FASã¹ãã¬ãŒãžã·ã¹ãã ãšé£æºããããã®ã€ãŒãµããããããã¯ãŒã¯ã®æé©åã«é¢ããå
·äœçãªæšå¥šäºé
ã瀺ããããšæããŸãã ãã ããããã§èª¬æããäºé
ã®å€ãã¯ãä»ã®ãœãªã¥ãŒã·ã§ã³ã«ã圹ç«ã€å¯èœæ§ããããšæããŸãã

ã€ãŒãµãããã®ãä¿¡é Œæ§ãã匷ãçã人ã®ããã«ã
FC 8Gãã10
GBEã«å®å
šã«åãæ¿ããããã«èª¬åŸãããããã§ã¯ãããŸããããæè¡ã«å¯Ÿããäžä¿¡ãšèª€è§£ã®ããç¹å®ã®é åãåé€ãããã®ã§ãã æè¡å°éå®¶ã¯ãåžžã«åççãã€ãå·éãªãæ
床ã§åé¡ã«åãçµãå¿
èŠããããŸãã åæã«ããã€ãŒãµãããããã¬ãŒã ã倱ã£ãŠããããšãã衚çŸã¯ããåãã®ãªãã¢ãããŒãããã䞻芳çæèããšã¯ã»ãšãã©èšããŸããã ã€ãŒãµãããã®ä¿¡é Œæ§ã«ã€ããŠã®ãã®ç¢ºåºããæèŠãã©ãããæ¥ãã®ããæ€èšããããšãææ¡ããŸãã
ãããã£ãŠãã€ãŒãµããããå
±æå軞ã±ãŒãã«ç°å¢ã䜿çšãã10Mbit / sã§ãã£ããšããããã¯ãã¹ãŠæšæºã®èªçããå§ãŸããŸããã ããã«ãæ
å ±ã®éä¿¡ã¯ãåäºéãã§ããã ããæç¹ã§ã1ã€ã®ããŒããŸãã¯æ
å ±ã®éä¿¡ãŸãã¯åä¿¡ã«ãã£ãŠæéãå®è¡ãããå¯èœæ§ããããŸãã ãã®ãããªãã¡ã€ã³ã®ãããã¯ãŒã¯ããŒããå€ãã»ã©ãè¡çªãå€ããªãããåäºéãã«ãã£ãŠç¶æ³ãæªåãããã¬ãŒã ã¯æ¬åœã«å€±ãããŸããã ãã®åŸãã€ãŒãµãããã¯ããã«äžæ©é²ã¿ããã€ã¹ããã¢ã±ãŒãã«ã䜿çšããŠå°æ¥ã®ããã¯ãã°ãæäŸãå§ããŸããããåãããã«æããªããããã¹ãŠã®ãããã¯ãŒã¯ããŒãã1ã€ã®ã³ãªãžã§ã³ãã¡ã€ã³ã«çµåããç¶æ³ã¯æ¬è³ªçã«å€ãããŸããã§ããã ãã¹ã€ããããšããèªãã®ããååã®ã¹ããŒãããã€ã¹ãç»å ŽããŸããã1ã€ã®ããŒãããå¥ã®ããŒãã«ãã¬ãŒã ãè€è£œããã ãã§ãªãããã¬ãŒã ã«ç»ã£ãŠããã¬ãŒã ã®éä¿¡å
ã®ã¢ãã¬ã¹ãšããŒããèšæ¶ããåä¿¡è
ããŒãã«ã®ã¿éä¿¡ããŸããã ãããŠããã¹ãŠãããŸããããŸãããè¡çªãã¡ã€ã³ã¯æçåãããã¹ã€ããããŒããæã€ããŒãã«ã®ã¿çž®å°ãããŠãããšããäºå®ã«ããããããã100Mbit / sã®ãããã¯ãŒã¯ã§ãè¡çªã¯äŸç¶ãšããŠäœããã®åœ¢ã§æ®ã£ãŠããŸãã圌ãããäºãã«ãã¬ãŒã ãåæã«éä¿¡ããããšãããšãã æ¬¡ã«èµ·ãã£ãããš-ããã¥ãã¬ãã¯ã¹ãïŒ10BASE-TãIEEE 802.3iïŒãã€ãŸã åããŒãã¯ãç°ãªããªã³ã¯ã§ãã¬ãŒã ãåæã«éåä¿¡ã§ããŸããããŒãçšã®RXãšTXã®2ã€ã®ãã¢ãšã¹ã€ããçšã®2ã€ã®ãã¢ã§ãã 1
GBEã§ã¯ãåäºéã¢ãŒãã¯ååšããŸããã ããã¯ã©ãããæå³ã§ããïŒ è¡çªã¯æ°žé ã«æ¶ããŸãã...圌ãã¯ãããããŸããã äºãã«å¯æ¥ã«é¢é£ãã2ã€ã®å°å
æã€ãŒãµãããçŸæ£ããããŸããããã¯ããããã¡ããªãŒããŒãããŒãããšã¹ã€ããããã¬ãŒã ããå¿ãããå¯èœæ§ããããããã¯éåžžãã«ãŒãããã¯ãïŒã€ãŒãµãããã«ãŒãïŒãåå ã§çºçããŸãã 1ïŒãã¹ã¬ã¹ã€ãŒãµããããšãåŒã°ããã€ãŒãµããããããã³ã«çšã®
DCBã¢ããªã³ã¯ã
FCã®å Žåã®ããã«ãã¬ãŒã ã倱ããªãããã«ãããããã³ã«ã®ã»ããã§ãã 2ïŒ
ããŒã¿ã»ã³ã¿ãŒã®ã¬ãã«ã¹ã€ããã«ã¡ã¢ãªã远å ããŸããã 3ïŒãããŠã10
GBEãããã¯ãŒã¯ãšç¹ã«ã·ã¹ã³ã¯ããã«äžæ©ãèžã¿åºãã
ããŒã¿ã»ã³ã¿ãŒåã
Nexusã¹ã€ããã®ã©ã€ã³ã§
TRILLãææ¡ããŸããã
TRILLãããã³ã«ãšFabricPathã¯ãã«ãŒãããã¯ãé²ãããã®IPãã±ããã®åç¶
æéãã£ãŒã«ããšåæ§ã«ãã€ãŒãµããããã¬ãŒã ã®æ°ãã
ãããã«ãŠã³ããã£ãŒã«ãã®ç®çãåã«æ±ºå®ããã ãã§ãªããIPãããåçšããããããã€ãã®æ©èœã«ãããæè¿ã®å°å
ç
ããã€ãŒãµããããæé€ããŸãã
NFS ã
iSCSI ã
CIFSãããã³ã«ã䜿çšããå Žåãå¯èœã§ããã°ã¹ã€ãããšãã¹ãã§
ãžã£ã³ããã¬ãŒã ãæå¹ã«ããããšããå§ãããŸãã NetApp
ã¹ãã¬ãŒãžã¯çŸåšã
MTU 9000ããµããŒãããŠããŸããããã¯ãæå€§ã®ã€ãŒãµããã10GBã§ãã ãã®å Žåã
ãžã£ã³ããã¬ãŒã ã¯ãã€ãŒãµããããã¬ãŒã ã®ã«ãŒãå
šäœïŒéä¿¡å
ããå®å
ïŒã«å«ããå¿
èŠããããŸãã æ®å¿µãªãããçŸæç¹ã§ã¯ãã¹ãŠã®ã¹ã€ããããã³ãã¹ãŠã®ãã¹ããããã¯ãŒã¯ã¢ããã¿ãŒããæå€§ã
MTUããµããŒãããŠããããã§ã¯ãããŸããããã®ããããµãŒããŒãšçµã¿èŸŒã¿10GBã¹ã€ãããåããHPãã¬ãŒãã·ã£ãŒã·ãé©çšãããšãæå€§8000
MTUããµããŒãããããã
ã¹ãã¬ãŒãžåŽã§æãå€ããéžæããå¿
èŠããããŸãé©åãª
MTUå€ã
MTUãäœã§ãããã«ã€ããŠå€å°ã®æ··ä¹±ããããããèšå®ããå¿
èŠããã
MTUå€ãçè§£ããã®ã¯å°é£ã§ãã ããšãã°ãã€ãŒãµãããã€ã³ã¿ãŒãã§ã€ã¹ã«
MTU 9000å€ãèšå®ãããNetApp
ã¹ãã¬ãŒãžã·ã¹ãã ã®éåžžã®åäœã§
㯠ã
MTUå€
ã 9000ïŒCatalyst 2970/2960/3750/3560ã·ãªãŒãºïŒã9198ïŒCatalyst 3850ïŒã®ããããã®å€
ã«èšå®ãããã¹ã€ããã§ãéåžžãåäœããŸãã ïŒã9216ïŒCisco Nexus 3000/5000/7000/9000ãCatalyst 6000/6500 / Cisco 7600 OSR SeriesïŒããã®ä»ã§ã¯äžè¬ã«ãã®å€ã¯9252ã§ããå¿
èŠããããŸããååãšããŠãã¹ã€ããã®
MTUãæå€§èš±å®¹å€ïŒ9000以äžïŒã«èšå®ããŸãã ïŒããã¹ãŠãæ©èœããŸãã æç¢ºã«ããããã«ã察å¿ããèšäº
Maximum Transmission UnitïŒMTUïŒãèªãããšããå§ãã
ãŸãã ç¥è©±ãšãµã³ãŽç€ ã

åãã¡ããªãã¯ã€ã³ã¿ãŒã³ãã¯ãã®ã³ãã³ãã©ã€ã³ããèšå®ãå®è¡ããŸãã
system jumbomtu 9216 policy-map type network-qos jumbo class type network-qos class-default mtu 9216 multi-cast-optimize exit system qos service-policy type network-qos jumbo exit copy run start
ãŸãã¯UCS Manager GUIããUCS Managerã®èšå®ã§ãã€ãŒãµãããã䜿çšããå ŽåããLan> Lan Cloud> QoS System Classãã¿ãã§MTUãèšå®ããéžæãã1ã€ã®ã¯ã©ã¹ã®MTUãèŠå®ããŸãã

次ã«ããQoSããªã·ãŒããäœæããŸã

vNICãã³ãã¬ãŒããäœæãã

ãµãŒããŒã®ãããã¯ãŒã¯ã€ã³ã¿ãŒãã§ã€ã¹ã«ãã€ã³ãããŸãã

ãããŒå¶åŸ¡èšå®
㯠ã
ã¹ãã¬ãŒãžããŒããšãããã«æ¥ç¶ãããŠããã¹ã€ããããŒãã®äž¡æ¹ã«
察å¿ããå¿
èŠã ãããŸãã ã€ãŸãã
ã¹ãã¬ãŒãžããŒãã®
ãããŒå¶åŸ¡ã
noneã«èšå®ãããŠããå Žåã
ã¹ã€ããã®ãããŒå¶åŸ¡ã¯
ãªãã«èšå®ããå¿
èŠãããããã®éãåæ§ã§ãã å¥ã®äŸïŒ
ã¹ãã¬ãŒãžã·ã¹ãã ã
flowcontrol sendãéä¿¡ãã
å Žå ãã¹ã€ããã¯ããããåä¿¡ããããã«èšå®ããå¿
èŠããããŸãïŒ
flowcontrol receive on ïŒã
ãããŒå¶åŸ¡èšå®ã®
äžæŽåã«ãã ã確ç«ããããããã³ã«ã»ãã·ã§ã³ïŒ
CIFSã
iSCSIãªã©ïŒãäžæããŸãããéä¿¡ã¯ç¶ç¶ããŸãããã»ãã·ã§ã³ãçµ¶ããäžæããããããªã³ã¯ã®è² è·ã倧ãããªããšåäœãéåžžã«é
ããªããè² è·ãå°ãããšãã«ã¯åé¡ã¯ãŸã£ããçºçããŸããã
- ååãšããŠãå¯èœã§ããã°ã flowcontrol TR-3428ãå«ããªãã§ãã ããã
- 10GBãããã¯ãŒã¯ã®å Žåã flowcontrolãæå¹ã«ããããšã¯åŒ·ãæšå¥šãããŸããã
- 1GBãããã¯ãŒã¯ã®å Žåã ãããŒå¶åŸ¡ãæå¹ã«ããããšãã§ããŸã ïŒã«ãŒã«ã®äŸå€ãšããŠïŒïŒ ã¹ãã¬ãŒãžã¯ãããŒå¶åŸ¡ãéä¿¡ããã¹ã€ããã¯åãå
¥ããŸã - ã¹ãã¬ãŒãžãšã¹ã€ããã§éä¿¡ããããã«ãããŒå¶åŸ¡ãèšå®ããŸã ïŒãŸãã¯éä¿¡/ txãªã ïŒ åä¿¡/ rxãªã³ ïŒã
- 100 MBãããã¯ãŒã¯ã®å ŽåïŒã«ãŒã«ã®äŸå€ãšããŠïŒãã¹ãã¬ãŒãžãšã¹ã€ããã®éåä¿¡ãããŒå¶åŸ¡ã³ãã³ãã®äž¡æ¹ã§åä¿¡ãšéä¿¡ã®ãããŒå¶åŸ¡ãæå¹ã«ã§ããŸãã
- ãã®ãããªæšèŠãããã«ããçç±ã«èå³ããã人ã
- TR - 3802ãåç
§ããŠãã ãã
- ã¹ãã¬ãŒãžããã³ã¹ã€ããèšå®ã®äŸã¯ãé¢é£èšäºã«èšèŒãããŠããŸãã
DCB ïŒãã¹ã¬ã¹ïŒEternetã®ãéåžžã®ãFlowControlãš
PFC ïŒIEEE 802.1QbbïŒãæ··åããªãã§ãã ããã
ãã¯ã©ã·ãã¯ã€ãŒãµããããïŒã€ãŸãããããŒã¿ã»ã³ã¿ãŒãã¬ãã«ã§ã¯ãªãã€ãŒãµãããïŒã§NetAppã䜿çšããå Žåã¯ã
RSTPãæå¹ã«ããŠããšã³ãããŒãïŒ
ã¹ãã¬ãŒãžãšãã¹ãïŒã
portfastãæå¹ã«ããŠæ¥ç¶ããã€ãŒãµãããããŒããæ§æããããšã匷ããå§ãããŸãã
TR-3749 ãããŒã¿ã»ã³ã¿ãŒãã¬ãã«ã®ã€ãŒãµããããããã¯ãŒã¯ã«ã¯ã¹ããã³ã°ããªãŒã¯ãŸã£ããå¿
èŠãããŸãã
ãvPCãã¯ãããžãŒãåããCisco Nexusã·ãªãŒãºã¹ã€ããã¯ããã®ãããªæ©åšã®äŸãšããŠäœ¿çšã§ããŸãã
10
GBEã®ãæ®éæ§ããèæ
®ããŠã
FCoE ã
NFS ã
CIFS ã
iSCSIã
vPCã
LACPãªã©ã®ãã¯ãããžãŒã®äœ¿çšãããã³ã€ãŒãµããããããã¯ãŒã¯ã®ã¡ã³ããã³ã¹ã®å®¹æããšãšãã«åãç©çåŠãééã§ãã
å Žåããããã³ã«ãšã¹ã€ããã
FCãã
åºå¥ããæ©äŒãæäŸããŸãå€åããããžãã¹ããŒãºã®å Žåã®ãæäœããšæè³ã®ä¿åã
NetApp
ã¹ãã¬ãŒãžã·ã¹ãã ã®å
éšãã¹ãïŒä»ã®
ã¹ãã¬ãŒãžãã³ããŒã§ã¯ããã®ç¶æ³ã¯ç°ãªãå ŽåããããŸãïŒ
FC 8Gããã³10
GBE iSCSI ã
CIFS ãããã³
NFS 㯠ã
OLTPããã³ãµãŒããŒããã³ãã¹ã¯ãããä»®æ³åã«å
žåçãªã
ã»ãŒåãããã©ãŒãã³ã¹ãšé
å»¶ã瀺ããŸãã å°ããªãããã¯ãšã©ã³ãã ãªèªã¿åãã®ããè² è·ã®å Žåã
ã€ãŒãµããããšFCã®é¡äŒŒç¹ãçžéç¹ãèŠéãã«ã€ããŠèª¬æããèšäºãããçè§£ããããšããå§ãããŸãã
ã客æ§ã®ã€ã³ãã©ã¹ãã©ã¯ãã£ã«2ã€ã®ã¹ã€ãããå«ãŸããå Žåã
SANãšã€ãŒãµããããããã¯ãŒã¯ã®äž¡æ¹ãã»ããã¢ããããåãè€éãã«ã€ããŠè©±ãããšãã§ããŸãã ããããå€ãã®ã客æ§ã«ãšã£ãŠã
SANãããã¯ãŒã¯ã¯ãå
šå¡ãå
šå¡ãèŠãã2ã€ã®
SANã¹ã€ããã«èŠçŽãããããšã¯ãªããååãšããŠæ§æã¯ããã§çµãããŸããããã®ç¹ã§ãã€ãŒãµãããã¡ã³ããã³ã¹ã¯ã¯ããã«ç°¡åã§ãã éåžžã顧客ã®ãããã¯ãŒã¯ã®
SAN㯠ãåé·ãªã³ã¯ãšãªã¢ãŒããµã€ããžã®ãªã³ã¯ãåãã倿°ã®ã¹ã€ããã§ãããæ±ºããŠç¶æããã®ã¯ç°¡åã§ã¯ãããŸããã ãŸããäœãåé¡ãçºçããå Žåã
Wiresharkã®ãã©ãã£ãã¯ã¯ãªãã¹ã³ããŠããŸããã
Cisco Nexus 5500ãªã©ã®ææ°ã®ã³ã³ããŒãžãã¹ã€ããã¯ãã€ãŒãµããããš
FCã®äž¡æ¹ã®ãã©ãã£ãã¯ãåãæ¿ããããšãã§ããããŒã€ã³ã¯ã³ãœãªã¥ãŒã·ã§ã³ã§å°æ¥ã®æè»æ§ãé«ããŸãã
ãŸããEtherChannel
LACPã䜿çšããããŒãéçŽã®å¯èœæ§ã«ã€ããŠãå¿ããªãã§ãã ããã ãŸããã¢ã°ãªã²ãŒã·ã§ã³ã¯ã€ãŒãµãããããŒããéæ³ã®ããã«çµåããã®ã§ã¯ãªãããã©ãã£ãã¯ããããã®éã§åæ£ïŒãã©ã³ã¹ïŒããã ãã§ããã€ãŸãã2ã€ã®ã¢ã°ãªã²ãŒãããã10
GBEããŒããåžžã«æå€§20
GBEã«å°éããããã§ã¯ãããŸããã ããã§ã
ã¹ãã¬ãŒãžããã¹ããšã¯å¥ã®IPãµããããã«ãããã©ããã«å¿ããŠãé©åãªãã©ã³ã¹æ¹æ³ãéžæããå¿
èŠãããããšã«æ³šæããŠãã ããã
SHDããã¹ããšã¯å¥ã®ãµããããã«ããå Žåãåžžã«åãã§ããããã
MACãã©ã³ã·ã³ã°ïŒå®å
ïŒãéžæã§ããŸãã-ã²ãŒããŠã§ã€ã®
MACã¢ãã¬ã¹ã
ã¹ãã¬ãŒãžã·ã¹ãã äžã®éçŽãªã³ã¯ã®æ°ããããã¹ããå°ãªãå Žåããããã¯ãŒã¯ããŒããã©ã³ã·ã³ã°ã¢ã«ãŽãªãºã ã®å®å
šæ§ãšå¶éãèæ
®ããŠããã©ã³ã·ã³ã°ã¯æé©ã«æ©èœããŸããã éããŸãåæ§ã§ããéçŽãªã³ã¯ã䜿çšãããããã¯ãŒã¯ããŒããå€ããªãããã©ã³ã·ã³ã°ã¢ã«ãŽãªãºã ããæ£ãããéžæãããã»ã©ãéçŽãªã³ã¯ã®æå€§åž¯åå¹
ã¯ãã¹ãŠã®ãªã³ã¯ã®åž¯åå¹
ã®
åèšã«è¿ã¥ããŸãã LACPãã©ã³ã·ã³ã°ã®è©³çްã«ã€ããŠã¯ãèšäºããªã³ã¯ã®
éçŽãšIPãã©ãã£ãã¯ã®ãã©ã³ã·ã³ã° ããåç
§ããŠãã ããã
TR-3749ã¯ãNetAppã¹ãã¬ãŒãžããã³Ciscoã¹ã€ããã䜿çšããŠVMWare ESXiãæ§æããéã®åŸ®åŠãª
éãã«ã€ããŠèª¬æããŠããŸãã
LACPã»ããã¢ããã®äŸNetApp 7-Mode
vif create lacp <vif name> -b ip {Port list}
NetApp Clustered ONTAPã§
ifgrp create -node <node name> -ifgrp <vif name> -distr-func {mac | ip | sequential | port} -mode multimode_lacp ifgrp add-port -node <node name> -ifgrp <vif name> -port {Port 1} ifgrp add-port -node <node name> -ifgrp <vif name> -port {Port 2}
NetAppãæ¥ç¶ããåã«portfastïŒã¹ããã³ã°ããªãŒããŒãã¿ã€ããšããžïŒãæ§æããå¿
èŠãããããšã«æ³šæããŠãã ããïŒCisco Catalystã¹ã€ããïŒ
cat(config)
Cisco Nexus 5000ã¹ã€ããïŒ
n5k(config)
æéãçµã€ã«ã€ããŠããããã¯ãŒã¯æé©åã«é¢ãããã®èšäºã«äœã远å ãããã®ããããšç¢ºä¿¡ããŠããŸãã®ã§ãéæããã«æ»ã£ãŠç¢ºèªããŠãã ããã
æ¬æã®èª€ããææ¡ã«ã€ããŠã¯PMã«ã³ã¡ã³ããéã£ãŠãã ããã