åã®èšäºã§ã
ãéFlexPod DCãã¢ãŒããã¯ãã£ã«ã€ããŠèª¬æããŸãããããã¯ãã¯ãªãã£ã«ã«ã€ã³ãã©ã¹ãã©ã¯ãã£ïŒSSCIïŒããã°ã©ã ã®ã·ã¹ã³ãœãªã¥ãŒã·ã§ã³ãµããŒããéããŠ1ã€ã®ãœãŒã¹ãããµããŒãã§ããŸãã ãã®äž»ãªæ©èœã¯ãNexusã·ãªãŒãºã¹ã€ããããªãããšã§ãããããã远å ãããšããã®ã¢ãŒããã¯ãã£ã¯å®å
šãªFlexPod DataCenterã«ãªããŸãã
ããã§ã¯ãNetApp
ã¹ãã¬ãŒãžã·ã¹ãã ã
UCSãã¡ã€ã³ã«çŽæ¥å«ãããFlexPod DataCenterã®æ°ãããããã¯ãŒã¯èšèšã«ã€ããŠèª¬æããŸãã
æšæºã®FlexPod DataCenterã¢ãŒããã¯ãã£ãšã®éãã¯ãNexusã¹ã€ããã
UCSãšNetAppã®éã«ãªãã
UCSã® ãäžãã«ããããšã§ãã
以åã®NetApp
FAS ã¹ãã¬ãŒãžã·ã¹ãã ãFabric InterconnectïŒFIïŒã«çŽæ¥æ¥ç¶ã§ãããšããäºå®ã«ãããããããå
¬åŒã«ã¯FlexPod DataCenterã¢ãŒããã¯ãã£ã¯ãã®ãããªèšèšãæäŸããŠããŸããã§ããã çŸåšãçŽæ¥æ¥ç¶èšèšããµããŒããããŠãããFlexPod DataCenterã¢ãŒããã¯ãã£ã®ããã«æŽçãããŠããŸãã

çŽæ¥æ¥ç¶ã«ãã
FCããã³
FCoEãããã¯ãŒã¯ã®å
šäœçãªèšèšã
äžã®ç»åã®ã¹ã€ããã³ã°åè·¯ã®èª¬æ2ã€ã®çç±ããã
FCãš
FCoEã®åææ¥ç¶ã衚瀺ãããŸãã
- ã ããããªãã¯æ¬åœã«ãããããããšãã§ããããã¯ããŸããã
- FCããã³/ãŸãã¯FCoEã§ããããšã瀺ãããã
2ã€ã®NetApp
FASã³ã³ãããŒã©ãŒéã®ã€ãŒãµãããæ¥ç¶ã¯ã次ã®2ã€ã®çç±ã§ç€ºãããŠããŸãã
- ãããã1ã€ã®ONã·ã¹ãã ã®2ã€ã®ããŒãã§ããããšã瀺ãããã«ïŒããã«ããŒããããå Žåã¯ãå³ã«ã¯ã©ã¹ã¿ãŒã¹ã€ããããããŸãïŒã
- å€éšã¯ã©ã¹ã¿ãŒãªã³ã¯ã¯ãClustered DataONTAPãªãã¬ãŒãã£ã³ã°ã·ã¹ãã ã«å¿
èŠãªã¢ã¯ã»ãµãªãŒã§ãã
FIããNexusã¹ã€ãããž
ã®FCãªã³ã¯ã¯ã次ã®2ã€ã®çç±ã§æãããŠããŸãã
- æªæ¥ã®ããã«ã NetAppãNexusã¹ã€ããã«åãæ¿ããå¿
èŠãããã FIãLUNã«ã¢ã¯ã»ã¹ã§ããããã«ãªããŸããã ãã®åŸãã¹ããŒã ãããã¹ã±ãŒã©ãã«ã«ãªãã UCSãã¡ã€ã³ã远å ããããšãå¯èœã«ãªããŸãã
- UCSãã¡ã€ã³ã«å«ãŸããŠããªãä»ã®ãµãŒããŒã®ã¹ãã¬ãŒãžãããªãœãŒã¹ãååŸããããã ããšãã°ã FIãŸãã¯ä»ã®ã¡ãŒã«ãŒã®ãµãŒããŒã«æ¥ç¶ãããŠããªãUCSã©ãã¯ãµãŒããŒïŒ UCS Cã·ãªãŒãºïŒã
ã€ãŒãµããããã©ãã£ãã¯ã®å ŽåãçŽæ¥æ¥ç¶ãš
iSCSIãããã³ã«ãããã³çŽæ¥æ¥ç¶ãš
FCPãããã³ã«-ãããã®ãããã³ã«ã«çµã¿èŸŒãŸãããã«ããã¹ã®å©ãã«ããããã©ãŒã«ããã¬ã©ã³ã¹ã®èšå®ãšãªã³ã¯ã«ãããã©ã³ã·ã³ã°ã«åé¡ã¯ãããŸããã
ãã ãã
çŽæ¥æ¥ç¶ã䜿çšããNASãããã³ã« ïŒ
NFS v2 /
NFS v3ããã³
CIFS v1 /
CIFS v2ïŒã®å Žåããããã®ãããã³ã«ã
LACPãªã©ã®ä»ã®ããŠã³ã¹ããªãŒã ãããã³ã«å
ã®è² è·åæ£ãšãã«ãããŒã·ã³ã°ã®äžè¶³ã®ãã
vPC ïŒ
FIã¯
vPCããµããŒãããŸããïŒã®ã§ãã€ãŒãµããããããã¯ãŒã¯ã®ãã©ãŒã«ããã¬ã©ã³ã¹ã¯äœããã®æ¹æ³ã§æ§ç¯ããå¿
èŠããããŸãã ããšãã°ãã€ãŒãµãããã®ãã©ãŒã«ããã¬ã©ã³ã¹ã¯ãä»®æ³ã¹ã€ããã¬ãã«ïŒãã®ãããªã¹ã€ããã®ããã©ãŒãã³ã¹ã«åé¡ãããå¯èœæ§ããããŸãïŒãŸãã¯
LACPã䜿çšããã«éçŽãããã¯ãŒã¯ãªã³ã¯ã®
ã¢ã¯ãã£ã/ããã·ãã¹ã€ããã³ã°ã䜿çš
ããããšã§å®è¡ã§ã
ãŸã ïŒå©çšå¯èœãªãã¹ãŠã®ãªã³ã¯ã§ãã©ãã£ãã¯ã忣ã§ããŸããïŒã
ã¹ãã¬ãŒãžåŽã®
ifgrp㯠ã
ã·ã³ã°ã«ã¢ãŒãã«èšå®ããå¿
èŠããã
ãŸã ã
NASãããã³ã«ã®çŽæ¥çãªã€ã³ã¯ã«ãŒãã®åé¡ã¯ã
NFS v4ããã³
CIFS v3.0ã§ã¯ããã»ã©æ·±å»ã§ã¯ãããŸãããããããã®ãããã³ã«ã®ã¯ã©ã€ã¢ã³ãããã³
ã¹ãã¬ãŒãžã®ãµããŒããå¿
èŠã§ãïŒ
cDOTã
åãããã¹ãŠã®
FASã·ã¹ãã ã¯
NFS v4ããã³
CIFS v3.0ããµããŒãã
ãŸã ïŒæçµçã«ãã«ãããã·ã³ã°ã®èŠãç®ãåŸãããŸããã
1ã€ã®ãªã³ã¯ã®äžã«FCoEããã³CIFS / NFSãã©ãã£ãã¯ãæ§æãã- ãŸããCisco UCSãã¡ãŒã ãŠã§ã¢ããŒãžã§ã³2.1以éãå¿
èŠã§ãã
- 次ã«ã10GB CNA / UTAããŒããåããã¹ãã¬ãŒãžãå¿
èŠã§ã
次ã«ãèšå®ã確èªããŸãã
NetAppã¹ãã¬ãŒãžåŽãããã¹ãã¬ãŒãžã§
ucadminã³ãã³ãã䜿çšããŠãããŒãã
CNAç¶æ
ã«ããå¿
èŠããããŸãïŒ
CNAããŒãã¯å¿
èŠãããŸãããéåžžã®ã€ãŒãµããã1 / 10GbsããŒãã¯ããããµããŒãããŸããïŒïŒ
ã¹ãã¬ãŒãžãåèµ·åããå¿
èŠããã
ãŸã ïŒã ã·ã¹ãã ã¯ãåå¥ã«ãä»®æ³ãã€ãŒãµãããããŒããšãä»®æ³ã
FCããŒããåå¥ã«è¡šç€ºããŸãïŒãã ããç©çããŒãã¯ãã®ãããªãä»®æ³ãã€ãŒãµããããš1ã€ã®ãä»®æ³ã
FCã«äœ¿çšãããŸãïŒã éåžžã®ç©çããŒããšåæ§ã«ãããŒãã¯åå¥ã«æ§æãããŸãã
FIã§ã¯ ããEquipmentãã¿ãã®Fabric A / Bèšå®ã§ããSwitching modeãç¶æ
ã®
FCã¢ãŒããæå¹
ã«ããå¿
èŠããããŸãã ãã®èšå®ã§ã¯ã
FIãåèµ·åããå¿
èŠããããŸãã
äžéšã®ããŒããFCã¢ãŒãã«è»¢éããå Žåã¯ã[æ©åš]ã¿ãã®[ãã¡ããªãã¯A / Bèšå®]ã§[çµ±åããŒãã®æ§æ]ãéžæãããŠã£ã¶ãŒãã§å¿
èŠãªæ°ã®FCããŒããéžæããŸãïŒå³åŽã§éžæãããŸãïŒã FIãåèµ·åããŸãã
FIãåèµ·åããåŸãEquipmentã¿ãã§ãåæããŒããŸãã¯FCããŒããã¢ãã©ã€ã¢ã³ã¹ããŒãã¢ãŒãã«åãæ¿ããå¿
èŠããããŸããæ°ç§åŸã«ããŒãããªã³ã©ã€ã³ã«ãªããŸãã æ¬¡ã«ãFCoEã¹ãã¬ãŒãžããŒãã¢ãŒããŸãã¯FCã¹ãã¬ãŒãžããŒãã¢ãŒãã§ããŒããåæ§æãããšãå³åŽã®ãã€ã³ã«ã
Unified Storage ããšããããŒãã®ã¿ã€ãã衚瀺ãããŸãã ããã§ããã®ãããªããŒãã«
VSANãš
VLANãéžæã§ããããã«ãªã
ãŸã ã ãŸãã
VSANã«ãã£ãŠä»¥åã«äœæãããéèŠãªãã€ã³ãã§ã¯ããŸãŒãã³ã°ãå®è¡ããããã«ã
FIã§ ãFCãŸãŒãã³ã°ããæå¹ã«ããå¿
èŠããã
ãŸã ã
FIã§ã®ãŸãŒãã³ã°ã®ã»ããã¢ããïŒ
SAN->ã¹ãã¬ãŒãžã¯ã©ãŠã->ãã¡ããªãã¯X-> VSANs->ãNetApp-VSAN-600ããäœæ->
VSAN IDïŒ600
FCoE VLAN IDïŒ3402
FCãŸãŒãã³ã°èšå®ïŒFCãŸãŒãã³ã°->æå¹
SAN->ããªã·ãŒ-> vHBAãã³ãã¬ãŒã-> "vHBA-T1"ãäœæ-> VSAN "NetApp-VSAN-600"
SAN->ããªã·ãŒ->ã¹ãã¬ãŒãžæ¥ç¶ããªã·ãŒ->ãMy-NetApp-Connãã®äœæ->ãŸãŒãã³ã°ã¿ã€ã-> SistïŒãŸãã¯å¿
èŠã«å¿ããŠSimtïŒ->äœæ->
FCã¿ãŒã²ãããšã³ããã€ã³ãïŒãNetApp LIFã®WWPNãïŒ20ããéå§:)
SAN->ããªã·ãŒ-> SANæ¥ç¶ããªã·ãŒ->ãNetApp-Conn-Pol1ããäœæ-> vHBAã€ãã·ãšãŒã¿ãŒã°ã«ãŒã->
ãiGroup1ããäœæ-> vHBAã€ãã·ãšãŒã¿ãŒãvHBA-T1ããéžæ
ã¹ãã¬ãŒãžæ¥ç¶ããªã·ãŒãéžæïŒãMy-NetApp-Connã
ãµãŒããŒãããã¡ã€ã«ãäœæãããšãã¯ãäœæããããªã·ãŒãšvHBAãã³ãã¬ãŒãã䜿çšããŸãã
以åã«FlexPod DataCenterã«çŽæ¥å«ããªãã£ãã®ã¯ãªãã§ããïŒ
äºå®ãæ°ãããœãªã¥ãŒã·ã§ã³ã§ã¯ãNetAppã¯ãã°ãã°ã远ãè¶ããªãããã远ãè¶ããæ¹ãè¯ãããšããã€ããªãã®ãŒãé å®ããŠããŸãã ãã®ããã
FAS ã¹ãã¬ãŒãžã·ã¹ãã çšã®Clustered ONTAP OSãäžã«åºããšããã¯ã©ã¹ã¿ãŒçžäºæ¥ç¶ã«
ã¯ãã®ã¿ã¹ã¯
å°çšã®å°çšNexus 5kã¹ã€ããïŒ1ãã«ïŒãå¿
èŠã§ãã ã æéãçµã€ã«ã€ããŠããã®æ§æã¯æ¹èšããã¹ãããã
ã¹ã€ããã¬ã¹æ§æã®æ©èœã远å ãããŸããã åæ§ã«ãã¹ãã¬ãŒãžã®çŽæ¥å
å«ã®ãã¹ããšãããã°ã«æéãããããæåã«ã¹ãã¬ãŒãžã®çŽæ¥æ¥ç¶ïŒçŽæ¥æ¥ç¶ããããžïŒã
åããCisco
UCS ManagerããŒã¹ã®FCãŸãŒãã³ã°ã®æ°ããããããžã
UCSãã¡ã€ã³ã«è¿œå ãããã¡ãŒã ãŠã§ã¢ããŒãžã§ã³
ãªãªãŒã¹2.1 ïŒ1aïŒã§å©çšå¯èœã«ãªããŸããã FlexPodã¢ãŒããã¯ãã£ã«ç»å ŽããŸããã
Nexusã¹ã€ãããå¿
èŠãªçç±
ã¢ã¯ã»ã¹ãããã³ã«
FC /
FCoE /
iSCSIã«ãããã¯ãããã³ã«ã䜿çšããå Žåãã¢ãŒããã¯ãã£ã®éãã®èгç¹ããã
FIã«
ã¹ãã¬ãŒãžãçŽæ¥å«ããæ§æã¯ãNexusã¹ã€ãããã¹ãã¬ãŒãžãš
UCSãã¡ã€ã³éã®ããªããžãšããŠæ©èœããå
ã®FlexPodèšèšãšã®éããæãå°ãªãã§ãã ãã ããæ°ããèšèšã§ã¯ã
Nexusã·ãªãŒãº
ã¹ã€ããã¯äŸç¶ãšããŠã¢ãŒããã¯ãã£ã®
éèŠãªã³ã³ããŒãã³ãã§ãã
- ãŸããFlexPodã¯äœããã®åœ¢ã§æ¢åã®ã€ã³ãã©ã¹ãã©ã¯ãã£ã«çµ±åããã顧客ãžã®ã¢ã¯ã»ã¹ãæäŸããå¿
èŠããããã
- 第äºã«ãçŽæ¥ã€ã³ã¯ã«ãŒããããšãå°æ¥ã®ã¢ãŒããã¯ãã£ã®ã¹ã±ãŒã©ããªãã£ãå¶éãããŸã
- 3çªç®ã«ã SAN ïŒ FC / FCoE / iSCSI ïŒãšã®çŽæ¥æ¥ç¶ãšã¯å¯Ÿç
§çã«ã NASã®ã€ãŒãµããããããã¯ãŒã¯ã®èšèšã§ã¯ããããã¯ãŒã¯ãªã³ã¯ã®è² è·åæ£ãå®è¡ããããã«ã¹ãã¬ãŒãžã·ã¹ãã ãšUCSãã¡ã€ã³éã®äžéãªã³ã¯ãããã³äž»ã«ãã©ãŒã«ããã¬ã©ã³ã¹æ©èœãå¿
èŠã§ãã
- 4çªç®ã«ãFlexPodãžã®å€éšã€ãŒãµãããã¯ã©ã€ã¢ã³ãã¢ã¯ã»ã¹ã¯ãã©ãŒã«ããã¬ã©ã³ãã§ãªããã°ãªããŸããã
SANãš
NASã®èšèšã®éãã¯ããããã¯ãããã³ã«ã®å Žåããã«ããã¹ãšãã©ã³ã·ã³ã°ã¡ã«ããºã ã
FC /
FCoE /
iSCSIãããã³ã«ã¬ãã«ã§å®è¡ããã
NFS /
CIFS ïŒ
SMB ïŒãããã³ã«ã䜿çšããå Žåããããã®ã¡ã«ããºã ãååšããªãããšã§ãã ãã«ããã¹ããã³ãã©ã³ã·ã³ã°æ©èœã¯ã
vPCããã³
LACPã䜿çšããŠã€ãŒãµãããã¬ãã«ã§å®è¡ããå¿
èŠããã
ãŸã ã ãã®ãããªèšèšã«ãããã¹ã€ããã®ååšã決å®ããèŠå ã§ãããã¹ã€ããã«ãã£ãŠã
Nexusã¹ã€ããã¯FlexPod DataCenterã¢ãŒããã¯ãã£ã®äžå¯æ¬ ãªã³ã³ããŒãã³ãã§ãããšããäºå®ã«ãããããããçŽæ¥æ¥ç¶ã«ãããè€åäœã®è©Šéè»¢ã®æåã®æ®µéã§ãã®ãããªãœãªã¥ãŒã·ã§ã³ã®ã³ã¹ããåæžãããŸãã æåã«Nexusã¹ã€ããã賌å
¥ããªãããã«ããŸãã ã€ãŸããæåã«
éFlexPod DCãæ§ç¯ã§ããŸãã ãããŠããã°ããããŠããã¹ã€ããã賌å
¥ããããèãã¬ã€ã€ãŒã§äºç®ã®ãªãŒããŒãããã忣ããå¿
èŠã«å¿ããŠããã¹ã±ãŒã©ãã«ãªFlexPod DataCenterã¢ãŒããã¯ãã£ãååŸããŸãã
ãã®åŸããããã¯ãŒã¯èšèšãããã¹ã±ãŒã©ãã«ãªãã®ã«å€æã§ããŸãããŸããã³ã³ããŒãã³ãã®éè€ã«ããããããè€åäœã忢ããããšãªãå®è¡ã§ããŸãã

å³2ã«ç€ºããããã¯ãŒã¯èšèšã®å¶éã¯ã
FCoEãšã€ãŒãµããããã©ãã£ãã¯ãåæã«ããããééããå Žåã1ã€ã®ã¹ãã¬ãŒãžã³ã³ãããŒã©ãŒããã¹ã€ãããžã®2ã€ã®ãªã³ã¯ã§ãã ã¹ãã¬ãŒãžããã®ãªã³ã¯æ°ãå¢ããå¿
èŠãããå Žåã¯ã
FCPãšã€ãŒãµããããã©ãã£ãã¯ãåå¥ã®å°çšããŒããšãªã³ã¯ã«åé¢ããå¿
èŠããããŸãã
FlexPodæ§æã®
å©ç¹ ã
ããŒã¿ã»ã³ã¿ãŒã¢ãŒããã¯ãã£ã®å®è£
ã«é¢ããæ°ããããã¥ã¡ã³ãããªãªãŒã¹ãããŸããïŒFlexPod ExpressãSelectãããã³DataCenter with Clustered Data ONTAPïŒcDOTïŒïŒ
ããã¹ãã®ãšã©ãŒã«é¢ããã¡ãã»ãŒãžãLANã«éã£ãŠãã ãããå察ã«ã³ã¡ã³ããšè¿œå ã¯ã³ã¡ã³ãããŠãã ãã