ãã®èšäºã§ã¯ãNokiaæ©åšïŒä»¥åã®Alcatel-LucentïŒã®åæã»ããã¢ããã®ããŒãã«ã€ããŠåŒãç¶ã説æããŸãã ãã®æ©åšã®æäœçµéšãããŸããªã人ã«ã圹ç«ã¡ãŸãããè¿ãå°æ¥ãå€åæéãNokia 7750ïŒSR-7 | SR-12ïŒã«é¢é£ä»ããèšç»ããããŸãã

ãããã¯ãŒã¯äžã®7750 SRã®äž»èŠãªçµ±åã®æé ãç解ããããšããŸãããç¹ã«èª¬æãããŠããæé ã¯æ°ãããœãããŠã§ã¢ããŒãžã§ã³ã§å€æŽãããå¯èœæ§ããããããã¡ãŒã«ãŒããã®å
¬åŒææžã眮ãæããããšãã§ããªãããšã«ããã«æ°ä»ããŸãã 7750ã®å®è¡ã«å¿
èŠãªæå°éã®æ
å ±ã®ã¿ã«å¶éãããããžã®ãªã¢ãŒãã¢ã¯ã»ã¹ãæäŸããäºå®ã§ãã ããã«ãããããããç§ã¯ãã®èšäºã«èå³ã瀺ãæ
å ±ã§ç°¡åã«è£è¶³ããŸãïŒãŸãã¯è³ªåãç¯å²ãè¶
ããŠããå Žåã¯æ°ããèšäºãæžããŸãïŒã
Nokia 7210 SAS-Mã®åææ§æã®ãããã¯ã«èå³ãããå Žåã¯ã 察å¿ããèšäºã§ãããããç解ã§ããŸãã
1. 7750 SRã®ãœãããŠã§ã¢ã¢ããããŒã
ãŸãããœãããŠã§ã¢ïŒTiMOSïŒãçŸåšã®ããŒãžã§ã³ã«æŽæ°ããããšããå§ãããŸãã 5620SAMå¶åŸ¡ã·ã¹ãã ã䜿çšããå ŽåããµããŒãããTiMOSã®æ倧ããŒãžã§ã³ãæ€èšããå¿
èŠãããããšã«ããã«æ³šæããŸãã
1.1ä»äºã®æºå
ä»äºã«å¿
èŠãªãã®ïŒ
1ïŒCOMããŒããŸãã¯usb-comã¢ããã¿ãŒãåããã©ãããããã
2ïŒã·ãªã¢ã«ã±ãŒãã«ã 7750ã³ã³ãœãŒã«ã¯DB9ã³ãã¯ã¿ã§ããããïŒRJ45ã䜿çšãã7210ãšã¯ç°ãªãïŒãè¿œå ã®ã¢ããã¿ãŒãåããCiscoããŒã«ãªãŒããŒã±ãŒãã«ã䜿çšããŸãã

3ïŒã¿ãŒããã«ã¯ã©ã€ã¢ã³ãïŒPuttyãSecureCRTãŸãã¯åçã®ãã®ïŒã
4ïŒTFTPãµãŒããŒïŒtftp32ãŸãã¯åçã®ãã®ïŒ;
5ïŒçŸåšã®TiMOSã®ååšïŒäŸãšããŠãTiMOS 13.0R10ã䜿çšïŒã
1.2å
å¡«ãœãããŠã§ã¢
ãœãããŠã§ã¢ãããŠã³ããŒãããã«ã¯ãã³ã³ãœãŒã«ããŒãã«æ¥ç¶ãã次ã®ããã«ã»ãã·ã§ã³ãã©ã¡ãŒã¿ãèšå®ããå¿
èŠããããŸãã
Baud Rate 115,200
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
管çããŒã7750ãçŽæ¥ã±ãŒãã«ã§ã³ã³ãã¥ãŒã¿ãŒã®ãããã¯ãŒã¯ã€ã³ã¿ãŒãã§ã€ã¹ã«ãŒãã«æ¥ç¶ããŸãã IPãããŒã«ã«ã³ã³ãã¥ãŒã¿ãŒã«èšå®ããŸãïŒäŸã§ã¯192.168.1.10/24ïŒã TFTPãµãŒããŒãèµ·åããäœæ¥ãã©ã«ããŒãšããŠTiMOSãå«ããã£ã¬ã¯ããªãéžæããŸãã
TiMOSãSRã«æ¢ã«ã€ã³ã¹ããŒã«ãããŠããå Žåã¯ãã¹ããã1.3ãã¹ãããããŠçŽæ¥1.4ã«é²ã¿ãŸãã
1.3æ©åšã«TiMOSããããŸããïŒã¢ãã¿ãŒã¢ãŒãïŒ
ä»»æã®ããŒãæŒããŠãããŒããã©ã¡ãŒã¿ã®å€æŽãéå§ããŸãã ãã¹ã¯ãŒãã®å
¥åãæ±ãããããããpasswordããšå
¥åããŸãã 次ã«ããã€ã¢ãã°ã«åŸã£ãŠãã ããïŒ
tftp://192.168.1.10/7750/TiMOS-SR-13.0.R10/both.tim
ãªãã¬ãŒãã£ã³ã°ã·ã¹ãã ã®ã¢ãã¬ã¹ãèšå®
tftp://192.168.1.10/7750/config.cfg
æ§æãã¡ã€ã«ã®ã¢ãã¬ã¹ãèšå®
enableã³ãã³ããèšè¿°ããŠeth-mgmtããŒãããªã³ã«ããã³ã³ãã¥ãŒã¿ãŒã§æ§æããã®ãšåããµããããããIPã¢ãã¬ã¹ãå²ãåœãŠãŸãã
æ§æãä¿åããããã«æ±ããããããçããŸã-ã¯ãã
ãã®æé ã®åŸããªãã¬ãŒãã£ã³ã°ã·ã¹ãã ãèµ·åããŸãã
1.4ã ããŒããŠã§ã¢èµ·åïŒTiMOSïŒ
ãã°ã€ã³/ãã¹ã¯ãŒãïŒadmin / admin
bof
ïŒããŒããªãã·ã§ã³ãã¡ã€ã«ã®ã»ããã¢ããã¡ãã¥ãŒã«ç§»åããŸã
no eth-mgmt-disabled
ïŒeth-mgmtããªã³ã«ãã
eth-mgmt-address 192.168.1.1/24
ã¢ãã¬ã¹ã7750ã«å²ãåœãŠãŸã
save
ïŒããŒããªãã·ã§ã³ãã¡ã€ã«ãä¿å
back
file dir
ïŒã¡ã¢ãªã«ãŒãã®ç©ºã容éã確èªãfile dir
ã ååãªã¡ã¢ãªããªãå Žåã¯ãã³ãã³ãfile delete "file name"ã䜿çšããŠãã¡ã€ã«ãåé€ã§ããŸãã
file md cf1:\TiMOS-13.0.R10
ïŒã¡ã¢ãªã«ãŒãã«æ°ããTiMOSã®ãã©ã«ããŒãäœæããã·ã¹ãã ãã¡ã€ã«ãããã«èªã¿èŸŒã¿ãŸã
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\both.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\cpm.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\iom.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\isa-aa.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\isa-tms.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\support.tim
file copy tftp://192.168.1.10/both.tim cf3:\TiMOS-13.0.R10\boot.ldr
file copy tftp://192.168.1.10/boot.tim cf3:\boot.ldr
ïŒããŠã³ããŒãïŒäžæžãïŒããŒãããŒããŒ
bof primary-image cf3:\TiMOS-13.0.R10\
ïŒèµ·åããã¡ã€ã³TiMOSã€ã¡ãŒãžãæå®ããŸã
bof secondary-image cf3:\< TiMOS, >
ïŒãªãã·ã§ã³
bof primary-config cf3:\config.cfg
ïŒæ§æãã¡ã€ã«ãæå®
bof no eth-mgmt-address 192.168.1.1/24
åé€
bof eth-mgmt-disabled
ïŒ bof eth-mgmt-disabled
bof save
admin save
æ©åšãã³ã³ãœãŒã«ã«æ¬¡ã®æ
å ±ã衚瀺ãããšããã¡ã€ã«ã¯æ£åžžã«ã³ããŒãããŸããã
Copying file tftp://192.168.1.10/both.tim ... OK
1 file copied.
æ§æãä¿åïŒadmin saveïŒããåŸã admin reboot upgrade
ã³ãã³ãã§7750ãadmin reboot upgrade
ããããŒããŠã§ã¢ãæ£åžžã«èµ·åããããšã確èªããå¿
èŠããããŸãã
1.5ã¹ã¿ã³ãã€ããã»ããµã¢ãžã¥ãŒã«ïŒã¹ã¿ã³ãã€CPMïŒ
ããã¯ã¢ããCPMã7750ã«ã€ã³ã¹ããŒã«ãããŠããå Žåã admin redundancy synchronize boot-env
ã³ãã³ãã䜿çšããŠãã·ã¹ãã ãã¡ã€ã«ãšæ§æãã¡ã¢ãªã«ãŒãïŒcf3-bã·ã¹ãã å
ïŒã«è»¢éããå¿
èŠããããŸãã
泚æïŒ 11åç®ã®ãªãªãŒã¹ä»¥éãæ°ããsupport.timãã¡ã€ã«ãç»å ŽããŸããã æŽæ°ã11æ¥ããåã®ããŒãžã§ã³ããå®è¡ãããå Žåããã®ãã¡ã€ã«copy cf3:\TiMOS-13.0.R10\support.tim cf3-b:\TiMOS-13.0.R10\support.tim
ããŠããã¯ã¢ããCPMã«æåã§ã³ããŒããå¿
èŠããããŸãã
/configure redundancy synchronize config
ã³ãã³ããå®è¡ããããšãå¿
èŠã§ãã ãã®æ§æãé©çšãããªãå Žåã admin save
ã³ãã³ãã¯æ§æãã¹ã¿ã³ãã€CPMã«admin save
ãŸããã
ããã¯ã¢ããã¢ãžã¥ãŒã«ããããšãIn-Service Software UpgradeïŒISSUïŒæé ãå®è¡ã§ããŸãã ãã®ãªãã·ã§ã³ã¯ãTiMOSã®æåã®ãã€ããŒããŒãžã§ã³ã§ã¯äœ¿çšã§ããŸãããã¢ããã°ã¬ãŒãããåã«ã察å¿ãããœãããŠã§ã¢ããŒãžã§ã³ã®ãœãããŠã§ã¢ãªãªãŒã¹ããŒããããç解ããå¿
èŠããããŸãã
ãã®æé ã«ã¯æ¬¡ã®ããŒã³ãã³ãããããŸãïŒæŽæ°ãéå§ãããæç¹ã§ãã¹ãããAã®CPMãã¢ã¯ãã£ãã§ãããšèããããŸãïŒã
- ã¡ã€ã³CPMã®cf3äžã®ãœãããŠã§ã¢ãcf3ãã©ã«ããŒã«ã³ããŒããŸãïŒ\ TiMOS-13.0.R10 \
- ã«ãŒãã®boot.ldrãæžãæããŸãïŒcf3 :)
- BOFã®ãã©ã€ããªããã³ããã¯ã¢ããTiMOSã€ã¡ãŒãžãžã®ãã¹ã®å€æŽ
admin redundancy synchronize boot-env
ïŒã¡ã€ã³ãšããã¯ã¢ããCPMã«ãŒããåæããŸãïŒå€ããªãªãŒã¹ã§support.timãæåã§ã³ããŒããããšãå¿ããã«ïŒadmin reboot standby now
ïŒããã¯ã¢ããã¢ãžã¥ãŒã«ãåèµ·åããŸããshow card
ïŒCPM-BããªããŒããã up ISSU/standby
ã¹ããŒã¿ã¹ãup ISSU/standby
ãŠããããšã確èªããŸãadmin redundancy force-switchove
ïŒæŽæ°ãããããã¯ã¢ããã¢ãžã¥ãŒã«ãã¢ã¯ãã£ãã«ããŸãã ãã®åŸã2çªç®ã®ïŒä»¥åã¢ã¯ãã£ãã ã£ãïŒã¢ãžã¥ãŒã«ãæŽæ°ããã»ã¹ãéå§ããŸããshow card
ïŒãã¹ãŠã®ã«ãŒããèµ·åããŠããããšã確èªããŸãã
2.ã«ãŒãã®ã€ã³ã¹ããŒã«ãšåæå
ã©ã€ã³ã«ãŒãã¯ãã·ã£ãŒã·ã®ç°ãªãéšåã«åãä»ããå¿
èŠããããŸãïŒSR-7ã§ã¯ãã©ã€ã³ã«ãŒãã2æããå Žåã4ãš5ã§ã¯ãªã1ãš5ã®ã¹ãããã«é
眮ããå¿
èŠããããŸãïŒã ããã¯ãã¿ã€ãã³ã°åºæºã®äœ¿çšã«é¢ããå¶éã«ãããã®ã§ãã Ref1ã¯1-2 / 1-5ã¹ãããã®ã«ãŒãã§ãRef2ã¯SR-7 / SR-12ã®3-5 / 6-10ã¹ãããã®ã«ãŒãã§ãããã䜿çšã§ããŸãã
2.1ã«ãŒãã®å®çŸ©
7750ã«ã€ã³ã¹ããŒã«ãããŠããã«ãŒããšã¢ãžã¥ãŒã«ã¯ãã¹ããŒã¿ã¹ãunequipped
ãŸã§ãæ§æã§æ±ºå®ããå¿
èŠããããŸã
configure card < >
card-type <equipped card-type>
mda < mda >
mda-type <equipped mda-type>
show cardããã³show mdaã®çºè¡ã«ãããæ£ããç¶æ
ã¯ãAdmin upãOperational upã§ãã ã«ãŒãã®è©³çŽ°æ
å ±ïŒP / NãS / Nã枩床ãªã©ïŒ detail
ã¯ãæå®ããã³ãã³ãã«detail
ãè¿œå ãdetail
ã
2.2ã·ã£ãŒã·ã¢ãŒã
configure system chassis-mode <>
ã³ãã³ãã䜿çšãããšãã·ã£ãŒã·ã§äœ¿çšã§ããæ©èœã®ã»ãããèšå®ã§ããŸãã ãã®ãã©ã¡ãŒã¿ãŒã¯ã䜿çšããã«ãŒãã®ã¿ã€ãã«ãã£ãŠç°ãªããŸãã
aïŒããã©ã«ãïŒïŒiom-20gã«é¢é£ããäžé£ã®æ©èœã«å¯Ÿå¿ããŸãã
bïŒiom-20g-bã«é¢é£ããäžé£ã®æ©èœã«å¯Ÿå¿ããŸãã
cïŒiom2-20gã«é¢é£ããäžé£ã®æ©èœã«å¯Ÿå¿ããŸãã
dïŒiom3-xpã«é¢é£ããäžé£ã®æ©èœã«å¯Ÿå¿
ããšãã°ãiom3-xpã«ãŒããã€ã³ã¹ããŒã«ãããŠããå Žåã configure system chassis-mode d
ã³ãã³ããå
¥åããå¿
èŠãããconfigure system chassis-mode d
3. 7750 SRã®åæã»ããã¢ããã®äŸ
/configure system name ""
ããŒããæºåããã€ã³ã¿ãŒãã§ã€ã¹ãäœæããŠé¢é£ä»ããŸãïŒ
/configure port 1/1/1
description " "
no shutdown
/configure router
interface "systemâ
address <IP >/32
ïŒã·ã¹ãã ä»®æ³ã€ã³ã¿ãŒãã§ã€ã¹ãäœæ
no shutdown
exit
interface " "
address <IP >/30
ïŒã€ã³ã¿ãŒãã§ãŒã¹ã®IPã¢ãã¬ã¹
port 1/1/1
ïŒãªã³ã¯ãåºãæ©åšã®ããŒã
no shutdown
exit
/configure router ospf
area 0.0.0.0
ïŒ7750ã«ãªããšãªã¢çªå·
interface "system"
ïŒãã®ã¢ãªã¢ã« "system"ã€ã³ã¿ãŒãã§ã€ã¹ãå«ããããã«ããŠãã ãã
exit
interface " "
ïŒãã®ã¢ãªã¢å
ã®ãã¹ãŠã®ã€ã³ã¿ãŒãã§ã€ã¹ã®ååãæå®ããŸã
interface-type point-to-point
ïŒã€ã³ã¿ãŒãã§ã€ã¹ã®ã¿ã€ããæå®ããŸã
exit
7750ãè€æ°ã®ã¢ãªã¢ã«åå ããŠããå Žåã2çªç®ã®ã¢ãªã¢ãšãã®ãã¹ãŠã®ã€ã³ã¿ãŒãã§ã€ã¹ãç»é²ããå¿
èŠããããŸãã ã€ã³ã¿ãŒãã§ã€ã¹ãã»ã«ã³ããªãšããŠéããã¯ããŒã³ãšãªã¢ã«åå ããå Žåã次ã®ããã«èšå®ãããŸãã
area 0.0.0.1 interface "system" secondary exit
ãã®æ§æã¯ãOSPFãããã³ã«ãæ§æããããããã¯ãŒã¯äžã®7750 SRã«ãªã¢ãŒãã§ã¢ã¯ã»ã¹ã§ããããã«ããããã®æå°éã®æ§æã§ãã
4.䟿å©ãªã¡ã¢
- ãadmin display-configãã³ãã³ãã§æ§æã衚瀺ã§ããŸãã ã³ã³ãœãŒã«ã®å Žæããã³ãã³ãïŒanyïŒãå®è¡ããå¿
èŠãããå Žåã¯ãæåã«ã/ããå
¥åããŸãã
- infoã³ãã³ããå®è¡ãããšãå Žæã®ãã©ã³ãã«é¢é£ããæ§æã確èªã§ããŸãã ãããã©ã«ãããã©ã¡ãŒã¿å€ã衚瀺ããå¿
èŠãããå Žåã¯ããæ
å ±ã®è©³çŽ°ãã䜿çšããŸã
- ãshow chassisãããã³ãshow cardãã³ãã³ãã䜿çšããŠãã·ã£ãŒã·ã®æž©åºŠãšFANåäœã¢ãŒãã確èªã§ããŸãã ãã¡ã³ãå
šéã¢ãŒãã§åäœããŠããå Žåãããã¯ãŠãããã®æž©åºŠãäžæããŠããããšã瀺ããŠããŸãã
- ããã¢ã®ã©ã€ã»ã³ã¹CFã«ãŒãã«ã¯TiMOSãšæ§æãå«ãŸããŠãããcf3ããã»ããµã«ãŒãã«ã€ã³ã¹ããŒã«ãããŸãã è¯ã解決çã¯ãè¿œå ã®Sandiskã¡ã¢ãªã«ãŒãïŒã¡ãŒã«ãŒã«ãã£ãŠå
¬åŒã«ãµããŒããããŠããïŒãcf2ãŸãã¯cf1ã¹ãããã«ã€ã³ã¹ããŒã«ãããã°ã¹ãã¬ãŒãžãšããŠäœ¿çšããããšã§ãã
- ãshow chassisãã³ãã³ãã䜿çšãããšãé»åãšãã®ç¯å²å€ã«é¢ããæ
å ±ãååŸã§ããŸãã
- ãshow log log-id 100ãããã³ãshow log log-id 99ãã³ãã³ãã䜿çšãããšãããããããã©ã«ãã®é倧ãšã©ãŒãã°ãšããã©ã«ãã®ã·ã¹ãã ãã°ã衚瀺ã§ããŸãã
- show portã³ãã³ãã¯ãããŒãã®ã¹ããŒã¿ã¹ã確èªããŸã
- show router route-tableã³ãã³ãã¯ã«ãŒãã£ã³ã°ããŒãã«ãåæ ããŸã
- cf3ïŒ/bootlog.txtãã¡ã€ã«ã§ãããŒããã°7750ãèŠã€ããããšãã§ããŸããæ©åšãTiMOSãããŒãã§ããªãå ŽåïŒããšãã°ããµã€ã¯ãªãã¯ãªããŒãã«ãªãå ŽåïŒããã®ãã¡ã€ã«ããã®æ
å ±ã¯èšºæã«åœ¹ç«ã¡ãŸãã
- IOSïŒCiscoïŒïŒãping 1.1.1.1ãµã€ãº1500 dfããããããã®å Žå1500ãã€ãã¯IPããã³ICMPããããŒãä»ããŠããããŒã¿ã°ã©ã ã®ãµã€ãºã§ãã
- TiMOSïŒNokiaïŒïŒãping 1.1.1.1ãµã€ãº1472ã-1472ãã€ãã¯ICMPã®ããŒã¿ãã£ãŒã«ãã®ãµã€ãºã瀺ããŸãã ã€ãŸãã8ãã€ãã®ICMPãš20ãã€ãã®IPãããã«è¿œå ããCiscoãšåã1500ãã€ããååŸããŸãã
- Nokiaã®ãã¯ãã«ã«ãµããŒãã«é£çµ¡ãããšãã¯ãã³ãã³ãã/ admin tech-support cf3ïŒ<ãã¡ã€ã«å> .binãã§æ®åœ±ãã2ã€ã®ãã¯ãã«ã«ãµããŒããã¡ã€ã«ã15å以äžã®æéå·®ã§æäŸããå¿
èŠããããŸãã æ®å¿µãªãããä»ã®å€ãã®ãã³ããŒãšã¯ç°ãªãããããã®ãã¡ã€ã«ã¯æå·åãããŠãããããã¢ã®ãšã³ãžãã¢ã®ã¿ãããããèªãããšãã§ããŸãã åé¡ãã¯ã©ãã·ã¥ãçºçããå Žåã¯ããŸãæåã®ãã¯ãã«ã«ãµããŒããã¡ã€ã«ãåé€ããŠãããåé¡ã®è§£æ±ºã«é²ãããšããå§ãããŸãã